電流表
電能表 概述 ●真正的RMS測量
●可編程電流互感器比率
(用于EPM34/14 1...1000/5A 1...5000/1A)
非易燃外殼
●雙隔離( ),Ⅲ類
●端子連接
●面板安裝或軌道安裝
●環境工作溫度:-50℃~+50℃
●用于EPM14/35 -50℃~+70℃ ●IEC61000-6-2, IEC 61000-6-4, IUEC61010-1 |
|
產品選擇表 |
|
|
3~電流 |
1~電流 |
CT-25(200A) |
雙重需求* |
…/1A |
…/5A |
需求 |
輸出觸點 |
軌道安裝 |
導軌安裝 |
固定電流端子 |
24-250V AC/DC |
件/紙箱 |
產品代碼 |
EPM-4A-72 |
帶CT-25電流表帶 |
(包括CT-25) |
|
● |
● |
|
|
● |
● |
|
● |
|
|
|
16 |
EPM-4A-96 |
CT-25電流表 |
(包括CT-25) |
|
● |
● |
|
|
● |
● |
|
● |
|
|
|
12 |
EPM-4C-48 |
電流表(帶輸出接觸) |
(包括CT-25) |
|
● |
● |
|
|
● |
● |
● |
● |
|
|
|
20 |
EPM-4C-72 |
電流表(帶輸出接觸) |
(包括CT-25) |
|
● |
● |
|
|
● |
● |
● |
● |
|
|
|
16 |
EPM-4C-96 |
電流表(帶輸出接觸) |
(包括CT-25) |
|
● |
● |
|
|
● |
● |
● |
● |
|
|
|
12 |
EPM-4C-OG-96 |
帶輸出觸點電流表( 用于MV應用) |
|
|
● |
|
|
|
● |
● |
● |
● |
|
● |
|
12 |
EPM-4D-48 |
電流表 |
|
|
● |
|
|
|
● |
● |
|
● |
|
|
|
20 |
EPM-4D-72 |
電流表 |
|
|
● |
|
|
|
● |
● |
|
● |
|
|
|
16 |
EPM-4D-96 |
電流表 |
|
|
● |
|
|
|
● |
● |
|
● |
|
|
|
12 |
EPM-4P-96 |
電流表 |
(包括CT-25) |
|
● |
● |
|
|
● |
● |
● |
● |
|
|
|
12 |
EPM-R4C |
帶輸出觸點電流表(導軌安裝) |
|
|
● |
|
|
|
● |
|
● |
|
● |
|
|
16 |
EPM-R4D |
電流表(導軌安裝) |
|
|
● |
|
|
|
● |
|
|
|
● |
|
|
16 |
EPM-14-96 |
電流表 |
|
|
● |
|
● |
● |
● |
|
|
● |
|
● |
● |
12 |
EPM-34-96 |
電流表 |
|
● |
|
|
● |
● |
● |
|
|
● |
|
● |
● |
12 |
變流器(用于ENTES面板儀表)CT-25 |
|
原線圈: 1/2500,內直徑: 15.5 mm,外直徑: 43 mm |
72 | 規格
|
EPM-4D |
EPM-4C |
EPM-4P |
EPM-34 |
EPM-4A |
EPM-R4D |
EPM-R4C |
外殼 |
|
|
|
|
|
|
|
尺寸 |
72x72mm PR18; Slim96 PR25, 48x96mm PR20 |
Slim96 PR25,48x96mm PR20 |
96x96mm PR19 |
72x72mm PR18; Slim96 PR25 |
DIN3 #4 PK20 |
重量 |
0.31kg/16件(PR18). 0.28kg/20件(PR20), 0.35kg/12件(PR25) |
0.34kg/件=12件 |
0.31kg/16件(PR18) 0.35kg/12件 (PR25) |
0.25kg/件#= 16件 |
顯示屏 |
紅色LED; 14mm.
|
紅色LED;12mm |
紅色LED;14mm |
紅色LED;10mm |
測量 |
準確度 |
1%±1位 |
0.5%±1位 |
1%±1位 |
負荷(輸入負載) |
|
電壓 |
測量范圍 |
50mA-5.5A
50mA-5,5A |
50mA-5.5A 70mA-200A帶CT25) |
5mA..5.5A (X/5A)
|
50mA-5.5A 70mA- 200A帶CT25) |
5mA...1.1A |
帶互感器測量范圍 |
50mA...10kA |
5mA…5500A |
50mA…10kA.. |
功耗(輸入負載) |
<0.5VA |
延遲時間 |
|
0-999.9秒 |
|
0-999.9秒 |
需求/需求時間 |
1-60分鐘 |
1-60min/1-60s |
1-60分鐘 |
電源 |
工作電壓 |
110/230V AC±10% |
24-250VAC/DC |
110/230VAC±10% |
功耗 |
4VA |
工作頻率 |
<45-65Hz |
輸出/設置 |
輸出接觸 |
|
1NO.5A 1250 VA |
|
1NO.5A 1250 VA |
標準 |
安全標準 |
EN 61010-1 |
EMC標準 |
EN 61000-4-2, EN 61000-6-4 |
機械耐久性 |
EN 60529 |
環境條件 |
工作溫度 |
-5/+50℃ |
-5/+70℃ |
-5/+50℃ |
過電壓類別 |
III |
連接 |
安裝 |
面板安裝 |
軌道安裝 |
連接端子 |
PR18,PR19帶插座螺旋; PK20螺旋 |
連續類型 |
單相2線 |
三相3線 |
單相2線 |
DC電流表 |
 |
概述 設備設計用于借助外部連接的旁路電阻器測量通過電力線輸送電流。 ●寬電源電壓,85-265 V AC/DC(DCA-10)、10-56V AC (DCA-11) ●利用MODBUS RTU協議在RS485線路上通信, ●存儲測量的最小和最大值, ●借助背光LCD屏幕可在任可照明條件下輕松查看設置井獲得最佳效果, ●測量時間可在1到600秒之間調整。 |
產品選擇表 |
|
電流 |
最大值 |
最小值 |
等級0.5 |
測量范圍+/-10ka直流 |
2個輸出觸點 |
模擬輸出(mA/V) |
Rs-485通信 |
Pano Tipi |
10-56 VDC |
85-265 VAC/DC |
件/紙箱 |
產品代碼 |
DCA-10 |
|
● |
● |
● |
● |
● |
|
|
|
● |
|
● |
20 |
DCA-10A |
|
● |
● |
● |
● |
● |
|
○ |
|
● |
|
● |
20 |
DCA-10C |
|
● |
● |
● |
● |
● |
● |
|
|
● |
|
● |
20 |
DCA-10S |
|
● |
● |
● |
● |
● |
|
|
● |
● |
|
● |
20 |
DCA-10CS |
|
● |
● |
● |
● |
● |
● |
|
● |
● |
|
● |
20 |
DCA-11 |
|
● |
● |
● |
● |
● |
|
|
|
● |
● |
|
20 |
DCA-11A |
|
● |
● |
● |
● |
● |
|
○ |
|
● |
● |
|
20 |
DCA-11C |
|
● |
● |
● |
● |
● |
● |
|
|
● |
● |
|
20 |
DCA-11S |
|
● |
● |
● |
● |
● |
|
|
● |
● |
● |
|
20 |
DCA-11CS |
|
● |
● |
● |
● |
● |
● |
|
● |
● |
● |
|
20 |
SA60-30 |
30A, 60mV Shunt |
|
|
|
|
|
|
|
|
|
|
|
1 |
SA60-40 |
40A, 60mV Shunt |
|
|
|
|
|
|
|
|
|
|
|
1 |
SA60-50 |
60A, 60mV Shunt |
|
|
|
|
|
|
|
|
|
|
|
1 |
SA60-60 |
100A, 60mV Shunt |
|
|
|
|
|
|
|
|
|
|
|
1 |
SA60-100 |
150A, 60mV Shunt |
|
|
|
|
|
|
|
|
|
|
|
1 |
SA60-150 |
250A, 60mV Shunt |
|
|
|
|
|
|
|
|
|
|
|
1 |
SA60-250 |
250A, 60mV Shunt |
|
|
|
|
|
|
|
|
|
|
|
1 |
SA60-500 |
500A, 60mV Shunt |
|
|
|
|
|
|
|
|
|
|
|
1 |
SA60-1000 |
1000A, 60mV Shunt |
|
|
|
|
|
|
|
|
|
|
|
1 |
|
DCA-10 |
DCA-10A |
DCA-10S |
DCA-10C |
DCA-10CS |
DCA-11 |
DCA-11A |
DCA-11S |
DCA-11C |
DCA-11CS |
外殼 |
尺寸 |
PR 20, 48x96 mm |
端子保護等級 |
IP 40 |
重量 |
0.240 kg |
顯示屏 |
2.5" 背光LCD屏幕 |
測量 |
測量輸入電阻器 |
1K |
精確度 |
0.5%±1位【 (10%-100%)×完整比例】 |
功耗(輸入負載) |
<1VA |
測量時間 |
1-600秒 |
電流 |
測量范圍 |
-10000A 10000A |
旁路電流 |
1A-10000A (10kA)
|
旁路電壓 |
50mV-150mV |
電源 |
工作電壓 |
85-265V AC/DC |
10-56V AC/DC |
功耗 |
<4 VA |
工作頻率 |
50-60 Hz |
標準 |
安全標準 |
EN 61010-1 |
EMC標準 |
EN 60255 |
機械耐久性 |
EN 60529 |
設備保護等級 |
雙絕緣-II類 |
端子保護等級 |
IP 00 |
環境條件 |
工作溫度 |
-20/-70℃ |
過電壓類別 |
III |
連接 |
安裝 |
面板安裝(PR 20) |
安裝等級 |
III |
連接端子 |
PR 20帶螺釘插座 |
連接類型 |
單相2線 |
電纜橫截面(對于端子) |
2.5 m㎡ |
通信 |
傳輸接口/協議 |
|
ModusRTU (R-485)可編程 |
|
ModusRTU (R-485)可編程 |
|
ModusRTU (R-485)可編程 |
|
ModusRTU(R-485)可編程 |
奇偶性 |
|
無,奇,偶 |
|
無,奇,偶 |
|
無,奇,偶 |
|
無,奇,偶 |
地址 |
|
1-247 |
|
1-247 |
|
1-247 |
|
1-247 |
傳輸安裝 |
|
2400-38400 |
|
2400-38400 |
|
2400-38400 |
|
2400-38400 | |
|
|
|
|
|
|
|