• <output id="7dvv4"></output>

  • 
    
          <output id="7dvv4"><tbody id="7dvv4"></tbody></output>

          <p id="7dvv4"></p>

            <wbr id="7dvv4"><dd id="7dvv4"></dd></wbr><output id="7dvv4"><em id="7dvv4"><kbd id="7dvv4"></kbd></em></output>

              Please select language:
              PRODUCT
              HOME >> PRODUCT >>
              power quality management
              power measurement
              power factor correction
              protection and control
               
               
              Reactive power compensation controller

              power factor correction
              Electrical system consumes both active and reactive power. ENTES power factor correction products are designed to prevent reactive power consumption. Help users avoid paying reactive power consumption costs, reduce all energy costs, and reduce line losses in transmission/distribution process. ENTES provides you with a complete compensation solution.

               

              Power Factor Controller
              ●RG3-C Series
              ●RG-B Series
              ●RG-T Series
              L.V. Capacitors
              ●ENT.C10 Series
              ●ENT.CXD Series
              ●ENT.C100 Series
              ●ENT.THN 40 Series
              ●ENT.THN 60 Series
              Shunt reactor
              ●ENT.ERS Series
              Tuned filter reactor
              ●ENT.ERH Series
              Line reactor
              ●ENT.SGR Series
              Capacitor load contactor
              ●ENT.KT Series
              Thyristor switch
              ●SC Series
              ●SPD harmonic protector
              Discharge device
              ●DU-3 Discharge Device
               
              RG/RG3 Series
              RG-T and RG-B/BS series power factor controllers compensate reactive power of balanced load by measuring the current information of a phase.
              RG3 series controllers compensate the reactive power of unbalanced system by measuring the current of three phases and the three phase voltages of the loads continuously changing between phases through three current transformers.
              The decisive solution of RG3-15CL/CLS controller is to control bypass reactor and capacitor to compensate for inductance and capacitance reactive power.

              ●Automatic Measurement of Capacitance Power in Each Loop
              ●Number of loops required for automatic detection
              ●Single-phase and three-phase capacitors can be connected to the network at the same time (RG3 series)
              ●Adjustable input, withdrawal and discharge time
              ●Adjustable Cos_value
              ●Programmable loop number
              ●Different input sequence of 10 kinds of programming
              ●Electric energy value can be used as electric energy meter (RG3 series)
              ●Preferential power ratio alarm in 1-240 hours

              Product Selection Table
              size(mm)
              Shunt reactor (3 steps)
              Intelligent conversion
              Single-phase Single Electric Currt Transformer
              3-Phase 3 Electric Currt Transformer
              Single-phase Capacitor
              Three-phase capacitor
              THD protect
              Double objective
              automatic settin
              Password protection
              RS-485 communication interface
              Internal temperature control
              External temperature control
              Package quantity
              Product code
              RG-12B
              12 steps
              144x144
              4
              RG-12BS
              12 steps
              144x144
              4
              RG3-12C
              12 steps
              144x144
              4
              RG3-12CS
              12 steps
              144x144
              4
              RG3-15C
              12 steps
              144x144
              4
              RG3-15CS
              12 steps
              144x144
              4
              RG3-15CL
              12 steps
              144x144
              4
              RG3-15CLS
              12 steps
              144x144
              4
              * RG3-15CL/CLSCan be ordered as 14C+1L or 12C+3L。   ○ Optional
              The three-phase capacitor for Reactive power all Out-off-balance Single-phase three-phase compensation capacitor for Reactive power, a separate compensation phaseOut-off-balance, RG-3 provides load balance and Out-off-balance a unique solution.

              RG / RG3 series
              RG-BS
              RG3-C/CL
              RG3-CS/CLS
              Shell
              size
              144x144mm PR16; 96x96mm PR19 (RG-8B/BS)
              Protection level
              IP40 front panel, IP54 Optional
              weight
              0.9kg/pcs (PR16); 0.6kg/pcs (PR19) (RG-8B/BS)
              measure/function
              accuracy
              1%±1位(V,I,cos );2%±1 (W,VAr,VA,harmonic)
              Overvoltage settin
              0-500 VAC
              0-300 VAC
              Electric current Range
              50mA-5.5A
              Transformer measuring range
              50mA-10kA Transformer ratio :1-2000
              burden (Input load)
              <2VA Electric current , < 3VA Voltage
              Cosф   settin
              0.8<cos  <1 Capacitance / inductance
              C / ksettin
              Steps between time delay
              2-1800 s A circuit for input / withdraw
              1-1800 s A circuit for input / withdraw
              Discharge time set
              2-1800s
              1-1800s
              Programmable THD-Valarm system
              Programmable dischargetime
              Programmable Overvoltage alarm system
              Automatic calculation steps
              electric energy measure
              Adjustable 節 electric energy 比例alarm system
              Displaying each phase parameter
              alarm systemContact output
              Power Supply
              working voltage
              230 VAC ± 10%
              working frequency
              50/60 Hz
              Power waste
              <10 VA
              input/outputsettin
              Step number
              6,8,12
              12,15
              Contact output
              5A,1250VA cosj=1
              environment condition
              working temperature
              - 5 ... +550C
              Ambient humidity
              85%
              Connect
              install
              Panel installation / helical terminal socket
              line type
              Single-phaseZero line,An Electric Currt Transformer
              3-Phase Zero Line,Three Electric Currt Transformers, Four Lines

               
               



              WEBSITE
              PRODUCT
              ENTES Electric Energy(Shanghai)Co.,Ltd.

              http://www.www.chinasantek.com

              Add:16th floor, first Shanghai plaza, 19 east gaolang road,Xinwu District,Wuxi City,Jiangsu Province,China
              Contact:Miss Yu
              Mobile:018961828820
              Tel:086-0510-85026586
              E-mail:3370878344@qq.com
              Copyright:ENTES Electric Energy(Shanghai)Co.,Ltd.
              亚洲欧美中文日韩V在线97,少妇张开雪白大腿,交换朋友夫妇2中文字幕,两对夫妇互换当面做真实视频